You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Welcome to the LW Scientific Support Portal

Showing articles from replacement tag

E8F and E8V Motor Drive Board Repair Instructions - SNR-7.5.1-W-008

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Fixed Centrifuge and E8 Variable Centrifuge. These instructions are valid for Revision J of the E8 Fixed and E8 Variable models. Required Equipment * Motor Drive Board (Part # 101283) * #1 Philips Scr…

Ready Warm Power Jack - SNR-7.5.1-W-046

Purpose This document provides instructions for replacing the power jack for the Ready Warm Tissue Bath. These instructions are valid for revision 6 of the Ready Warm. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This work instru…

MX12 Interface Board - SNR-7.5.1-W-031

Purpose This work instruction describes the process to replace the User Interface Board on the MX12 Centrifuges. Required Equipment * User Interface Board * The full list of required equipment is not available in the provided document content. Summary of Process This procedure outlines the steps for replaci…

E8T Motor Drive Board Repair Instructions - SNR-7.5.1-W-006

Purpose This document provides instructions for replacing the soft start motor drive board in the E8 Touch Centrifuge. These instructions are valid for E8 Touch Revisions A and B. Required Equipment * Motor Drive Board (Part # 101283) * #1 Philips Screwdriver Summary of Process The procedure involves unpluggi…

MX12 Lid Instruction - SNR-7.5.1-W-022

Purpose This work instruction describes the process for replacing the lid on the MX12 centrifuge unit. Required Equipment * Lid (Part # 100959-F) * Lid Latch Top Plate (Part # 100961-E) * Solenoid Latch Catch (Part # 101078-E) * Hinge Plate (Part # 100960-C) * Machined Screw M4x8mm BHCS SS (Part # 101071) …

Incubator Magnet Replacement Instructions - SNR-7.5.1-W-026

Purpose This work instruction describes the process to replace the door magnet of 10L, 20L, and 30L Incubators. Required Equipment * Stainless Steel Covered Magnet (Part # 101407) * 2 mm Hex Key Summary of Process The procedure involves opening the incubator door, unscrewing the old magnet with a 2mm Hex Key,…

MX5 Lid Latch Repair Instructions - SNR-7.5.1-W-044

Purpose This work instruction describes the process of replacing the MX5 lid latch. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The repair procedure involves replacing the lid latch on an MX5 Digital Centrifuge. The attached doc…

MX5 User Interface Board Repair Instructions - SNR-7.5.1-W-041

Purpose This work instruction describes the process for replacing the User Interface Board (100919-C) of the MX5 Centrifuge. Required Equipment * User Interface Board (Part # 100919-C) Summary of Process This document provides instructions for replacing the user interface board of the MX5 Digital Centrifuge. T…

MXU Fuse Repair Instruction - SNR-7.5.1-W-007

Purpose This work instruction describes the process for replacing the MXU Fuse. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Fuse; 3A; 250V (Part # 100084) * 1/8” Flathead Screwdriver Summary of Process The procedure involves unplugging the unit, removing the mot…

Mx12 Lid Latch Repair - SNR-7.5.1-W-001

Purpose This work instruction describes the process for replacing the lid latch on MX12 centrifuge units. Required Equipment * Replacement Lid Latch Summary of Process This document provides instructions for replacing the lid latch on an MX12 centrifuge. The procedure involves the removal of the old latch an…

scroll to top icon