E8D Motor Drive Board Repair Instructions - SNR-7.5.1-W-010

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…

MX5 Motor Repair Instructions - SNR-7.5.1-W-045

Purpose This work instruction describes the process of replacing the motor in an MX5 Centrifuge. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the motor on an MX5 Centrifuge. The a…

MXU Power Jack Repair Instructions - SNR-7.5.1-W-014

Purpose This work instruction describes the process for replacing the MXU Power Jack. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Power Jack Wiring Assembly (Part # 100300) * Phillips Head Screwdriver * Crescent Wrench Summary of Process The repair procedure…

MX12 Hinge Instruction - SNR-7.5.1-W-021

Purpose This work instruction describes the process for replacing the hinge on MX12 centrifuge units. Required Equipment * Black Plastic Hinge; adjustable friction (Part # 101323) * Machine Screw; M4 X 0.7; 8mm; Black Oxide (Part # 100996) * 2.5mm hex driver Summary of Process The procedure involves turning …

MX5 Label Replacement Instructions - SNR-7.5.1-W-043

Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…

E8F & E8V Timer Repair Instructions - SNR-7.5.1-W-016

Purpose This work instruction describes the process for repairing the Timer Knob of the E8 Fixed and E8 Variable Centrifuges. These instructions are valid for Revision J of both models. Required Equipment * Timer (Part # 100203-B) * 10 mm socket * #1 Philips screwdriver Summary of Process The repair proced…

MX12 Motor Replacement Instruction - SNR-7.5.1-W-034

Purpose This work instruction describes the process of replacing the motor in the MX12 Centrifuge. Required Equipment * Motor (Part # 100968-B or 100994-B) Summary of Process The procedure involves replacing the motor in an MX12 centrifuge. The attached document provides a step-by-step guide on how to perform …

E8F and E8V Lid Switch Repair Instructions - SNR-7.5.1-W-017

Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…

MXU Speed Sensor Repair Instructions - SNR-7.5.1-W-012

Purpose This work instruction describes the process for replacing the MXU Speed Sensor on a revision C MXU Digital Centrifuge. Required Equipment * Speed Sensor (Part # 100271-C) * Phillips Head Screwdriver Summary of Process The repair process involves opening the centrifuge, removing the rotor and base plate,…

MXU Power Switch Repair Instruction - SNR-7.5.1-W-009

Purpose This work instruction describes the process for replacing the power switch (100413) on a revision C MXU Digital Centrifuge. Required Equipment * Power Switch (Part # 100413) * Phillips Head Screwdriver Summary of Process The repair procedure involves removing the rotor and tube shields, inverting the …