MXU Speed Sensor Repair Instructions - SNR-7.5.1-W-012

Purpose This work instruction describes the process for replacing the MXU Speed Sensor on a revision C MXU Digital Centrifuge. Required Equipment * Speed Sensor (Part # 100271-C) * Phillips Head Screwdriver Summary of Process The repair process involves opening the centrifuge, removing the rotor and base plate,…

MXU Power Switch Repair Instruction - SNR-7.5.1-W-009

Purpose This work instruction describes the process for replacing the power switch (100413) on a revision C MXU Digital Centrifuge. Required Equipment * Power Switch (Part # 100413) * Phillips Head Screwdriver Summary of Process The repair procedure involves removing the rotor and tube shields, inverting the …

E8 Speed Wheel Replacement Instructions - SNR-7.5.1-W-028

Purpose This work instruction describes how to replace a speed wheel assembly, which includes two speed sensor hubs and one hub stop. Required Equipment * Speed Sensor Wheel (Part # 100482) * Speed Sensor Hub (Part # 100481) * Speed Sensor Hub Stop (Part # 100487) * #1 Philips Screwdriver Summary of Proc…

E8 Lid Latch Replacement Instructions - SNR-7.5.1-W-027

Purpose This document describes the procedure for replacing the E8 Lid Latch. These instructions are valid for E8V rev F, E8F rev D, and E8T rev F. Required Equipment * Latch (Part # 100073) * Cam Latch; 1.5” (Part # 100473) * #1 Screwdriver * Loc-Tite Blue 425 * Hios CL-6500 electric driver with #3 Phill…

MX5 Fuse Repair Instructions - SNR-7.5.1-W-042

Purpose This work instruction describes the process of replacing the MX5 Fuse. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the fuse on an MX5 Digital Centrifuge. The attached doc…

MX12 Lid Gasket Instruction - SNR-7.5.1-W-030

Purpose This work instruction describes the process for replacing the lid gasket of MX12 centrifuge units. Required Equipment * Lid Gasket (Part # from content) Summary of Process The procedure involves removing the old lid gasket and installing a new one to ensure proper function and seal of the centrifuge …

Ready Warm Power Switch - SNR-7.5.1-W-047

Purpose This work instruction describes how to replace the power switch for the Ready Warm Tissue Bath. These instructions are valid for revision 6. Required Equipment * Power Switch (Part # 100099) * 2mm Hex Wrench Summary of Process The repair procedure involves unplugging the unit, removing the screws, rep…

Motor Control Board - SNR-7.5.1-W-032

Purpose This work instruction describes the process to replace the Motor Control Board on the MX12 Centrifuges. Required Equipment * User Interface Board Summary of Process This document provides instructions for replacing the MX12 Motor Control Board. The procedure involves removing the existing board and ins…

Ready Warm Power Jack - SNR-7.5.1-W-046

Purpose This document provides instructions for replacing the power jack for the Ready Warm Tissue Bath. These instructions are valid for revision 6 of the Ready Warm. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This work instru…

MX5 Motor Control Drive Board Repair Instructions - SNR-7.5.1-W-037

Purpose This work instruction describes the process for replacing the Motor Control Board on the MX5 Digital Centrifuge. The instructions apply to boards with part numbers 100918-B for 110V units and 101072 for 220V units. Required Equipment * Motor Control Board (Part # 100918-B for 110V or 101072 for 220V) Su…