E8F and E8V Motor Drive Board Repair Instructions - SNR-7.5.1-W-008

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Fixed Centrifuge and E8 Variable Centrifuge. These instructions are valid for Revision J of the E8 Fixed and E8 Variable models. Required Equipment * Motor Drive Board (Part # 101283) * #1 Philips Scr…

MX12 Interface Board - SNR-7.5.1-W-031

Purpose This work instruction describes the process to replace the User Interface Board on the MX12 Centrifuges. Required Equipment * User Interface Board * The full list of required equipment is not available in the provided document content. Summary of Process This procedure outlines the steps for replaci…

Tissue Bath Repair Instructions - SNR-7.5.1-W-033

Purpose These repair instructions provide sequential details for the complete disassembly and reassembly process for the Ready Warm Tissue Bath. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides a detailed guide…

E8T Motor Drive Board Repair Instructions - SNR-7.5.1-W-006

Purpose This document provides instructions for replacing the soft start motor drive board in the E8 Touch Centrifuge. These instructions are valid for E8 Touch Revisions A and B. Required Equipment * Motor Drive Board (Part # 101283) * #1 Philips Screwdriver Summary of Process The procedure involves unpluggi…

MX12 Lid Instruction - SNR-7.5.1-W-022

Purpose This work instruction describes the process for replacing the lid on the MX12 centrifuge unit. Required Equipment * Lid (Part # 100959-F) * Lid Latch Top Plate (Part # 100961-E) * Solenoid Latch Catch (Part # 101078-E) * Hinge Plate (Part # 100960-C) * Machined Screw M4x8mm BHCS SS (Part # 101071) …

Incubator Magnet Replacement Instructions - SNR-7.5.1-W-026

Purpose This work instruction describes the process to replace the door magnet of 10L, 20L, and 30L Incubators. Required Equipment * Stainless Steel Covered Magnet (Part # 101407) * 2 mm Hex Key Summary of Process The procedure involves opening the incubator door, unscrewing the old magnet with a 2mm Hex Key,…

MX5 Lid Latch Repair Instructions - SNR-7.5.1-W-044

Purpose This work instruction describes the process of replacing the MX5 lid latch. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The repair procedure involves replacing the lid latch on an MX5 Digital Centrifuge. The attached doc…

MX5 User Interface Board Repair Instructions - SNR-7.5.1-W-041

Purpose This work instruction describes the process for replacing the User Interface Board (100919-C) of the MX5 Centrifuge. Required Equipment * User Interface Board (Part # 100919-C) Summary of Process This document provides instructions for replacing the user interface board of the MX5 Digital Centrifuge. T…

MXU Fuse Repair Instruction - SNR-7.5.1-W-007

Purpose This work instruction describes the process for replacing the MXU Fuse. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Fuse; 3A; 250V (Part # 100084) * 1/8” Flathead Screwdriver Summary of Process The procedure involves unplugging the unit, removing the mot…

MX12 Base Conversion Instructions - SNR-7.5.1-W-002

Purpose This work instruction describes the process for converting the base of MX12 centrifuge units. Summary of Process This document provides instructions for converting the base of the MX12 centrifuge. The attached document provides a detailed, step-by-step guide for this procedure, which is valid for Revis…