Power Input Replacement Instructions - SNR-7.5.1-W-035 MX12

Purpose This work instruction describes the process of replacing the Power Input on the MX12 centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the power input on an MX…

MXU Solenoid Repair Instructions - SNR-7.5.1-W-015

Purpose This work instruction describes the process for replacing the MXU Solenoid. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Solenoid; 12V (Part # 100079) * Phillips head screwdriver * #7 nut driver or #7 socket with socket wrench Summary of Process The…

MX12 Interface Board - SNR-7.5.1-W-031

Purpose This work instruction describes the process to replace the User Interface Board on the MX12 Centrifuges. Required Equipment * User Interface Board (Part # 100919) Summary of Process This document provides instructions for replacing the user interface board. The procedure involves opening the unit, disc…

Motor Control Board - SNR-7.5.1-W-032

Purpose This work instruction describes the process to replace the Motor Control Board on the MX12 Centrifuges. Required Equipment * User Interface Board Summary of Process This document provides instructions for replacing the MX12 Motor Control Board. The procedure involves removing the existing board and ins…

E8 Power Switch Replacement Instructions - SNR-7.5.1-W-024

Purpose This work instruction describes how to replace a power switch for all versions of the E8 centrifuge. Required Equipment * Switch; power input; round body; illuminated red (Part # 100099) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and ba…

MX5 Label Replacement Instructions - SNR-7.5.1-W-043

Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…

MX12 Fuse Replacement Instructions - SNR-7.5.1-W-036

Purpose This work instruction describes the process of replacing the Fuse on the MX12 centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the fuse on an MX12 centrifuge. T…

E8 Digital Fuse Replacement Instructions - SNR-7.5.1-W-039

Purpose This work instruction describes the process for replacing the motor drive board fuse in the E8 Digital Centrifuge. These repair instructions are valid for the E8 Digital Centrifuge. Required Equipment * Fuse; 2A, 250V (Part # 100084) * 1/8” Flathead Screwdriver * #1 Philips Screwdriver Summary of Pr…

E8 Lid Repair Instructions - SNR-7.5.1-W-040

Purpose This work instruction describes the process for replacing the lid of all E8 Centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The procedure involves the complete process for replacing the lid on any E8 Centrifug…

MXU Motor Control Board Repair Instructions - SNR-7.5.1-W-011

Purpose This work instruction describes the process for replacing the MXU Motor Control Board. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Motor Control Board (Part # 100484) * Needle Nose Pliers * Screwdriver Summary of Process The repair procedure invo…