E8 Lid Repair Instructions - SNR-7.5.1-W-040

Purpose This work instruction describes the process for replacing the lid of all E8 Centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The procedure involves the complete process for replacing the lid on any E8 Centrifug…

MXU Motor Control Board Repair Instructions - SNR-7.5.1-W-011

Purpose This work instruction describes the process for replacing the MXU Motor Control Board. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Motor Control Board (Part # 100484) * Needle Nose Pliers * Screwdriver Summary of Process The repair procedure invo…

MXU Speed Wheel Repair Instructions - SNR-7.5.1-W-013

Purpose This document provides instructions for replacing the MXU Speed Wheel on revision C MXU Digital Centrifuges. Required Equipment * Speed Sensor Wheel (Part # 101103) * Speed Sensor Hub (Part # 101104) * Speed Sensor Hub Stop (Part # 101105) * Blind Rivet, SS (Part # 100787) * Phillips Head Screwdri…

E8D Motor Drive Board Repair Instructions - SNR-7.5.1-W-010

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…

E8 Speed Tach Sensor Replacement Instructions - SNR-7.5.1-W-025

Purpose This work instruction describes how to replace a speed/tach sensor on the E8V Revision J and E8F Revision J centrifuge models. Required Equipment * IR Sensor (Part # 101070) * #1 Phillips screwdriver Summary of Process The repair procedure involves unplugging the unit and removing the rotor and ba…

E8 Power Jack Replacement Instructions - SNR-7.5.1-W-023

Purpose This work instruction describes the process to replace a power jack for all versions of the E8 Centrifuge. Required Equipment * Power Jack Cable Assembly; E8 (Part # 100525) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and base/motor asse…

E8 Lid Latch Replacement Instructions - SNR-7.5.1-W-027

Purpose This document describes the procedure for replacing the E8 Lid Latch. These instructions are valid for E8V rev F, E8F rev D, and E8T rev F. Required Equipment * Latch (Part # 100073) * Cam Latch; 1.5” (Part # 100473) * #1 Screwdriver * Loc-Tite Blue 425 * Hios CL-6500 electric driver with #3 Phill…

MXU Speed Sensor Repair Instructions - SNR-7.5.1-W-012

Purpose This work instruction describes the process for replacing the MXU Speed Sensor on a revision C MXU Digital Centrifuge. Required Equipment * Speed Sensor (Part # 100271-C) * Phillips Head Screwdriver Summary of Process The repair process involves opening the centrifuge, removing the rotor and base plate,…

MX12 Hinge Instruction - SNR-7.5.1-W-021

Purpose This work instruction describes the process for replacing the hinge on MX12 centrifuge units. Required Equipment * Black Plastic Hinge; adjustable friction (Part # 101323) * Machine Screw; M4 X 0.7; 8mm; Black Oxide (Part # 100996) * 2.5mm hex driver Summary of Process The procedure involves turning …

E8F and E8V Lid Switch Repair Instructions - SNR-7.5.1-W-017

Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…